CVEvulnerability

CVE-2011-3322

10.0 HIGH Published 2011-09-15 Modified 2026-06-16 Official page ↗
Status
Modified
Published
2011-09-15
Last modified
2026-06-16
Assigner
[email protected]
CVSS 2.0 ([email protected])
10.0 HIGH — AV:N/AC:L/Au:N/C:C/I:C/A:C
Weaknesses
CWE-119

Description

Core Server HMI Service (Coreservice.exe) in Scadatec Limited Procyon SCADA 1.06, and other versions before 1.14, allows remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long password to the Telnet (TCP/23) port, which triggers an out-of-bounds read or write, leading to a stack-based buffer overflow.

Affected configurations

• scadatec procyon scada 1.06 • scadatec procyon scada 1.13

Related

Weakness · CWE (1)

  • CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer weakness

References