CVEvulnerability

CVE-2013-3075

10.0 HIGH Published 2013-04-19 Modified 2026-06-16 Official page ↗
Status
Modified
Published
2013-04-19
Last modified
2026-06-16
Assigner
[email protected]
CVSS 2.0 ([email protected])
10.0 HIGH — AV:N/AC:L/Au:N/C:C/I:C/A:C
Weaknesses
CWE-119

Description

Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control.

Affected configurations

• mitsubishi-automation mitsubishi mx component 3 • schneider-electric citectfacilities 7.10 • schneider-electric citectscada 7.10

Related

Weakness · CWE (1)

  • CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer weakness

References