CVEvulnerability

CVE-2015-1014

7.3 HIGH Published 2019-03-25 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2019-03-25
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.0 ([email protected])
7.3 HIGH — CVSS:3.0/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
CVSS 2.0 ([email protected])
4.4 MEDIUM — AV:L/AC:M/Au:N/C:P/I:P/A:P
Weaknesses
CWE-427

Description

A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version.

Affected configurations

• schneider-electric opc factory server 3.5

Related

Weakness · CWE (1)

  • CWE-427 Uncontrolled Search Path Element weakness

References