CVEvulnerability

CVE-2015-7907

8.6 HIGH Published 2015-12-21 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2015-12-21
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.0 ([email protected])
8.6 HIGH — CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:L
CVSS 2.0 ([email protected])
6.4 MEDIUM — AV:N/AC:L/Au:N/C:N/I:P/A:P
Weaknesses
CWE-22

Description

Directory traversal vulnerability in the web server on Honeywell Midas gas detectors before 1.13b3 and Midas Black gas detectors before 2.13b3 allows remote attackers to bypass authentication, and write to a configuration file or trigger a calibration or test, via unspecified vectors.

Affected configurations

• honeywell midas black firmware (<= 2.13b1) • honeywell midas firmware (<= 1.13b1)

Related

Weakness · CWE (1)

  • CWE-22 Improper Limitation of a Pathname to a Restricted Directory weakness

References