CVEvulnerability

CVE-2016-7090

4.0 MEDIUM Published 2016-09-29 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2016-09-29
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.0 ([email protected])
4.0 MEDIUM — CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:N/A:N
CVSS 2.0 ([email protected])
4.3 MEDIUM — AV:N/AC:M/Au:N/C:P/I:N/A:N
Weaknesses
CWE-200

Description

The integrated web server on Siemens SCALANCE M-800 and S615 modules with firmware before 4.02 does not set the secure flag for the session cookie in an https session, which makes it easier for remote attackers to capture this cookie by intercepting its transmission within an http session.

Affected configurations

• siemens scalance m-800 firmware (<= 4.01) • siemens scalance s615 firmware (<= 4.01)

Related

Weakness · CWE (1)

  • CWE-200 Exposure of Sensitive Information to an Unauthorized Actor weakness

References