CVEvulnerability
CVE-2017-9967
7.8 HIGH
Official page ↗
- Status
- Modified
- Published
- 2018-02-12
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 3.0 ([email protected])
- 7.8 HIGH — CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- CVSS 2.0 ([email protected])
- 4.6 MEDIUM — AV:L/AC:L/Au:N/C:P/I:P/A:P
Description
A security misconfiguration vulnerability exists in Schneider Electric's IGSS SCADA Software versions 12 and prior. Security configuration settings such as Address Space Layout Randomization (ASLR) and Data Execution prevention (DEP) were not properly configured resulting in weak security.
Affected configurations
• schneider-electric interactive graphical scada system (<= 12.0)
References
- http://www.securityfocus.com/bid/103022 Third Party Advisory, VDB Entry
- https://www.schneider-electric.com/en/download/document/SEVD-2018-037-01/ Vendor Advisory
- http://www.securityfocus.com/bid/103022 Third Party Advisory, VDB Entry
- https://www.schneider-electric.com/en/download/document/SEVD-2018-037-01/ Vendor Advisory