CVEvulnerability

CVE-2018-10594

9.8 CRITICAL Published 2018-06-26 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2018-06-26
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.0 ([email protected])
9.8 CRITICAL — CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0 ([email protected])
7.5 HIGH — AV:N/AC:L/Au:N/C:P/I:P/A:P
Weaknesses
CWE-119, CWE-121

Description

Delta Industrial Automation COMMGR from Delta Electronics versions 1.08 and prior with accompanying PLC Simulators (DVPSimulator EH2, EH3, ES2, SE, SS2 and AHSIM_5x0, AHSIM_5x1) utilize a fixed-length stack buffer where an unverified length value can be read from the network packets via a specific network port, causing the buffer to be overwritten. This may allow remote code execution, cause the application to crash, or result in a denial-of-service condition in the application server.

Affected configurations

• deltaww commgr (<= 1.08)

Related

Weakness · CWE (2)

  • CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer weakness
  • CWE-121 Stack-based Buffer Overflow weakness

References