CVEvulnerability

CVE-2018-11311

9.1 CRITICAL Published 2018-05-20 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2018-05-20
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.0 ([email protected])
9.1 CRITICAL — CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
CVSS 2.0 ([email protected])
6.4 MEDIUM — AV:N/AC:L/Au:N/C:P/I:P/A:N
Weaknesses
CWE-798

Description

A hardcoded FTP username of myscada and password of Vikuk63 in 'myscadagate.exe' in mySCADA myPRO 7 allows remote attackers to access the FTP server on port 2121, and upload files or list directories, by entering these credentials.

Affected configurations

• myscada mypro 7.0

Related

Weakness · CWE (1)

  • CWE-798 Use of Hard-coded Credentials weakness