8.6 HIGH Published 2018-08-07 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2018-08-07
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.0 ([email protected])
8.6 HIGH — CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H
CVSS 2.0 ([email protected])
4.4 MEDIUM — AV:L/AC:M/Au:N/C:P/I:P/A:P
Weaknesses
CWE-276, CWE-732

Description

A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V10, V11, V12 (All versions), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V13 (All versions < V13 SP2 Update 2), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V14 (All versions < V14 SP1 Update 6), SIMATIC STEP 7 (TIA Portal) and WinCC (TIA Portal) V15 (All versions < V15 Update 2). Improper file permissions in the default installation of TIA Portal may allow an attacker with local file system access to manipulate resources which may be transferred to devices and executed there by a different user. No special privileges are required, but the victim needs to transfer the manipulated files to a device. Execution is caused on the target device rather than on the PG device.

Affected configurations

• siemens simatic step 7 \(tia portal\) 10.0 • siemens simatic step 7 \(tia portal\) 11.0 • siemens simatic step 7 \(tia portal\) 12.0 • siemens simatic step 7 \(tia portal\) 13.0 • siemens simatic step 7 \(tia portal\) 14.0 • siemens simatic step 7 \(tia portal\) 15.0 • siemens simatic wincc \(tia portal\) 10.0 • siemens simatic wincc \(tia portal\) 11.0 • siemens simatic wincc \(tia portal\) 12.0 • siemens simatic wincc \(tia portal\) 13.0 • siemens simatic wincc \(tia portal\) 14.0 • siemens simatic wincc \(tia portal\) 15.0

Related

Weakness · CWE (2)

  • CWE-276 Incorrect Default Permissions weakness
  • CWE-732 Incorrect Permission Assignment for Critical Resource weakness