9.8 CRITICAL Published 2018-12-12 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2018-12-12
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.0 ([email protected])
9.8 CRITICAL — CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0 ([email protected])
7.5 HIGH — AV:N/AC:L/Au:N/C:P/I:P/A:P
Weaknesses
CWE-248

Description

A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). Specially crafted network packets sent to port 102/tcp (ISO-TSAP) could allow a remote attacker to either cause a Denial-of-Service condition of the integrated software firewall or allow to execute code in the context of the software firewall. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 102/tcp. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known

Affected configurations

• siemens sinumerik 808d v4.7 firmware • siemens sinumerik 808d v4.8 firmware • siemens sinumerik 840d sl v4.7 firmware (<= 4.7) • siemens sinumerik 840d sl v4.8 firmware (<= 4.8) • siemens sinumerik 828d v4.7 firmware (<= 4.7)

Related

Weakness · CWE (1)

  • CWE-248 Uncaught Exception weakness