CVEvulnerability
CVE-2018-1244
8.8 HIGH
Official page ↗
- Status
- Modified
- Published
- 2018-07-02
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 3.0 ([email protected])
- 8.8 HIGH — CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- CVSS 3.0 ([email protected])
- 8.8 HIGH — CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- CVSS 2.0 ([email protected])
- 6.5 MEDIUM — AV:N/AC:L/Au:S/C:P/I:P/A:P
- Weaknesses
- CWE-77
Description
Dell EMC iDRAC7/iDRAC8, versions prior to 2.60.60.60, and iDRAC9 versions prior to 3.21.21.21 contain a command injection vulnerability in the SNMP agent. A remote authenticated malicious iDRAC user with configuration privileges could potentially exploit this vulnerability to execute arbitrary commands on the iDRAC where SNMP alerting is enabled.
Affected configurations
• dell idrac7 firmware (< 2.60.60.60)
• dell idrac8 firmware (< 2.60.60.60)
• dell idrac9 firmware (< 3.21.21.21)
Related
Weakness · CWE (1)
- CWE-77 Improper Neutralization of Special Elements used in a Command weakness
References
- http://en.community.dell.com/techcenter/extras/m/white_papers/20487494 Vendor Advisory
- http://www.securityfocus.com/bid/104964 Third Party Advisory, VDB Entry
- http://en.community.dell.com/techcenter/extras/m/white_papers/20487494 Vendor Advisory
- http://www.securityfocus.com/bid/104964 Third Party Advisory, VDB Entry