CVEvulnerability

CVE-2018-13813

8.1 HIGH Published 2018-12-13 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2018-12-13
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.0 ([email protected])
8.1 HIGH — CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:N
CVSS 2.0 ([email protected])
5.8 MEDIUM — AV:N/AC:M/Au:N/C:P/I:P/A:N
Weaknesses
CWE-601

Description

A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The webserver of affected HMI devices may allow URL redirections to untrusted websites. An attacker must trick a valid user who is authenticated to the device into clicking on a malicious link to exploit the vulnerability. At the time of advisory publication no public exploitation of this security vulnerability was known.

Affected configurations

• siemens simatic hmi comfort panels firmware (<= 15.0) • siemens simatic hmi comfort outdoor panels firmware (<= 15.0) • siemens simatic hmi ktp mobile panels ktp400f firmware (<= 15.0) • siemens simatic hmi ktp mobile panels ktp700 firmware (<= 15.0) • siemens simatic hmi ktp mobile panels ktp700f firmware (<= 15.0) • siemens simatic hmi ktp mobile panels ktp900 firmware (<= 15.0) • siemens simatic hmi ktp mobile panels ktp900f firmware (<= 15.0) • siemens simatic wincc \(tia portal\) (<= 15.0) • siemens simatic wincc runtime (<= 15.0) • siemens simatic hmi tp firmware • siemens simatic hmi mp firmware • siemens simatic hmi op firmware

Related

Weakness · CWE (1)

  • CWE-601 URL Redirection to Untrusted Site weakness

References