CVEvulnerability
CVE-2018-20100
9.8 CRITICAL
Official page ↗
- Status
- Modified
- Published
- 2019-01-02
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 3.0 ([email protected])
- 9.8 CRITICAL — CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- CVSS 2.0 ([email protected])
- 5.0 MEDIUM — AV:N/AC:L/Au:N/C:P/I:N/A:N
- Weaknesses
- CWE-311
Description
An issue was discovered on August Connect devices. Insecure data transfer between the August app and August Connect during configuration allows attackers to discover home Wi-Fi credentials. This data transfer uses an unencrypted access point for these credentials, and passes them in an HTTP POST, using the AugustWifiDevice class, with data encrypted with a fixed key found obfuscated in the app.
Affected configurations
• august august connect
• august august connect firmware
Related
Weakness · CWE (1)
- CWE-311 Missing Encryption of Sensitive Data weakness
References
- https://dojo.bullguard.com/dojo-by-bullguard/blog/august-connect/ Third Party Advisory
- https://dojo.bullguard.com/dojo-by-bullguard/blog/august-connect/ Third Party Advisory