CVEvulnerability
CVE-2018-4854
8.8 HIGH
Official page ↗
- Status
- Modified
- Published
- 2018-07-03
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 3.0 ([email protected])
- 8.8 HIGH — CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
- CVSS 2.0 ([email protected])
- 9.3 HIGH — AV:N/AC:M/Au:N/C:C/I:C/A:C
- Weaknesses
- CWE-306
Description
A vulnerability has been identified in SICLOCK TC100 (All versions) and SICLOCK TC400 (All versions). An attacker with network access to port 69/udp could modify the administrative client stored on the device. If a legitimate user downloads and executes the modified client from the affected device, then he/she could obtain code execution on the client system.
Affected configurations
• siemens siclock tc400 firmware
• siemens siclock tc100 firmware
Related
Weakness · CWE (1)
- CWE-306 Missing Authentication for Critical Functionality weakness
References
- http://www.securityfocus.com/bid/104672 Third Party Advisory, VDB Entry
- https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf Mitigation, Vendor Advisory
- http://www.securityfocus.com/bid/104672 Third Party Advisory, VDB Entry
- https://cert-portal.siemens.com/productcert/pdf/ssa-197012.pdf Mitigation, Vendor Advisory