CVEvulnerability
CVE-2019-0014
7.5 HIGH
Official page ↗
- Status
- Modified
- Published
- 2019-01-15
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 3.0 ([email protected])
- 7.5 HIGH — CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- CVSS 3.0 ([email protected])
- 7.5 HIGH — CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- CVSS 2.0 ([email protected])
- 5.0 MEDIUM — AV:N/AC:L/Au:N/C:N/I:N/A:P
- Weaknesses
- CWE-19
Description
On QFX and PTX Series, receipt of a malformed packet for J-Flow sampling might crash the FPC (Flexible PIC Concentrator) process which causes all interfaces to go down. By continuously sending the offending packet, an attacker can repeatedly crash the FPC process causing a sustained Denial of Service (DoS). This issue affects both IPv4 and IPv6 packet processing. Affected releases are Juniper Networks Junos OS on QFX and PTX Series: 17.4 versions prior to 17.4R2-S1, 17.4R3; 18.1 versions prior to 18.1R3-S1; 18.2 versions prior to 18.2R1-S3, 18.2R2; 17.2X75 versions prior to 17.2X75-D91, 17.2X75-D100.
Affected configurations
• juniper junos 17.2x75
• juniper junos 17.4
• juniper junos 18.2
Related
Weakness · not in database (1)
References
- http://www.securityfocus.com/bid/106556 Third Party Advisory, VDB Entry
- https://kb.juniper.net/JSA10914 Mitigation, Patch, Vendor Advisory
- http://www.securityfocus.com/bid/106556 Third Party Advisory, VDB Entry
- https://kb.juniper.net/JSA10914 Mitigation, Patch, Vendor Advisory