CVEvulnerability

CVE-2019-0060

7.5 HIGH Published 2019-10-09 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2019-10-09
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.1 ([email protected])
7.5 HIGH — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CVSS 3.1 ([email protected])
7.5 HIGH — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CVSS 2.0 ([email protected])
5.0 MEDIUM — AV:N/AC:L/Au:N/C:N/I:N/A:P
Weaknesses
CWE-755

Description

The flowd process, responsible for forwarding traffic in SRX Series services gateways, may crash and restart when processing specific transit IP packets through an IPSec tunnel. Continued processing of these packets may result in an extended Denial of Service (DoS) condition. This issue only occurs when IPSec tunnels are configured. Systems without IPSec tunnel configurations are not vulnerable to this issue. This issue affects Juniper Networks Junos OS: 15.1X49 versions prior to 15.1X49-D171, 15.1X49-D180 on SRX Series; 18.2 versions 18.2R2-S1 and later, prior to 18.2R3 on SRX Series; 18.4 versions prior to 18.4R2 on SRX Series.

Affected configurations

• juniper junos 15.1x49 • juniper junos 18.2 • juniper junos 18.4

Related

Weakness · CWE (1)

  • CWE-755 Improper Handling of Exceptional Conditions weakness

References