CVEvulnerability

CVE-2019-12310

9.8 CRITICAL Published 2019-06-03 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2019-06-03
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.0 ([email protected])
9.8 CRITICAL — CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0 ([email protected])
5.0 MEDIUM — AV:N/AC:L/Au:N/C:P/I:N/A:N
Weaknesses
CWE-22

Description

ExaGrid appliances with firmware version v4.8.1.1044.P50 have a /monitor/data/Upgrade/ directory traversal vulnerability, which allows remote attackers to view and retrieve verbose logging information. Files within this directory were observed to contain sensitive run-time information, including Base64 encoded 'support' credentials, leading to administrative access of the device.

Affected configurations

• exagrid backup appliance firmware 48.1.1044.p50

Related

Weakness · CWE (1)

  • CWE-22 Improper Limitation of a Pathname to a Restricted Directory weakness

References