CVEvulnerability

CVE-2019-13205

7.5 HIGH Published 2020-03-13 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2020-03-13
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.1 ([email protected])
7.5 HIGH — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
CVSS 2.0 ([email protected])
5.0 MEDIUM — AV:N/AC:L/Au:N/C:P/I:N/A:N
Weaknesses
CWE-306

Description

All configuration parameters of certain Kyocera printers (such as the ECOSYS M5526cdw 2R7_2000.001.701) were accessible by unauthenticated users. This information was only presented in the menus when authenticated, and the pages that loaded this information were also protected. However, all files that contained the configuration parameters were accessible. These files contained sensitive information, such as users, community strings, and other passwords configured in the printer.

Affected configurations

• kyocera ecosys m5526cdw firmware 2r7 2000.001.701

Related

Weakness · CWE (1)

  • CWE-306 Missing Authentication for Critical Functionality weakness

References