CVEvulnerability

CVE-2019-13924

5.4 MEDIUM Published 2020-02-11 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2020-02-11
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.1 ([email protected])
5.4 MEDIUM — CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N
CVSS 2.0 ([email protected])
4.3 MEDIUM — AV:N/AC:M/Au:N/C:N/I:P/A:N
Weaknesses
CWE-1021, CWE-693

Description

A vulnerability has been identified in SCALANCE S602 (All versions < V4.1), SCALANCE S612 (All versions < V4.1), SCALANCE S623 (All versions < V4.1), SCALANCE S627-2M (All versions < V4.1), SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < 5.2.4), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < 4.1.3). The device does not send the X-Frame-Option Header in the administrative web interface, which makes it vulnerable to Clickjacking attacks. The security vulnerability could be exploited by an attacker that is able to trick an administrative user with a valid session on the target device into clicking on a website controlled by the attacker. The vulnerability could allow an attacker to perform administrative actions via the web interface.

Affected configurations

• siemens scalance xc-200 firmware (< 5.2.4) • siemens scalance xf-200 firmware (< 5.2.4) • siemens scalance xp-200 firmware (< 5.2.4) • siemens scalance x-200irt firmware • siemens scalance xb-200 firmware (< 5.2.4) • siemens scalance xr-300wg firmware (< 4.1.3) • siemens scalance x-300 firmware (< 4.1.3) • siemens scalance xr-300 firmware (< 4.1.3)

Related

Weakness · CWE (2)

  • CWE-1021 Improper Restriction of Rendered UI Layers or Frames weakness
  • CWE-693 Protection Mechanism Failure weakness

References