CVEvulnerability
CVE-2019-13929
6.5 MEDIUM
Official page ↗
- Status
- Modified
- Published
- 2019-10-10
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 3.1 ([email protected])
- 6.5 MEDIUM — CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
- CVSS 2.0 ([email protected])
- 4.0 MEDIUM — AV:N/AC:L/Au:S/C:P/I:N/A:N
- Weaknesses
- CWE-321, CWE-330
Description
A vulnerability has been identified in SIMATIC IT UADM (All versions < V1.3). An authenticated remote attacker with network access to port 1434/tcp of SIMATIC IT UADM could potentially recover a password that can be used to gain read and write access to the related TeamCenter station. The security vulnerability could be exploited only if the attacker is authenticated. No user interaction is required to exploit this security vulnerability. Successful exploitation of the security vulnerability compromises the confidentiality of the targeted system. At the time of advisory publication no public exploitation of this security vulnerability was known.
Affected configurations
• siemens simatic it uadm (< 1.3)
Related
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf Vendor Advisory
- https://cert-portal.siemens.com/productcert/pdf/ssa-984700.pdf Vendor Advisory