CVEvulnerability
CVE-2019-18341
5.3 MEDIUM
Official page ↗
- Status
- Modified
- Published
- 2019-12-12
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 3.1 ([email protected])
- 5.3 MEDIUM — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
- CVSS 3.1 ([email protected])
- 5.3 MEDIUM — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
- CVSS 2.0 ([email protected])
- 5.0 MEDIUM — AV:N/AC:L/Au:N/C:P/I:N/A:N
- Weaknesses
- CWE-287
Description
A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0). The SFTP service (default port 22/tcp) of the Control Center Server
(CCS) contains an authentication bypass vulnerability.
A remote attacker with network access to the CCS server could
exploit this vulnerability to read data from the EDIR directory
(for example, the list of all configured stations).
Affected configurations
• siemens sinvr 3 central control server
• siemens sinvr 3 video server
Related
Weakness · CWE (1)
- CWE-287 Improper Authentication weakness
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf Vendor Advisory
- https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf cert-portal.siemens.com
- https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf Vendor Advisory
- https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf cert-portal.siemens.com