CVEvulnerability
CVE-2019-18994
6.5 MEDIUM
Official page ↗
- Status
- Modified
- Published
- 2019-12-18
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 3.1 ([email protected])
- 3.9 LOW — CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:N/I:L/A:L
- CVSS 3.1 ([email protected])
- 6.5 MEDIUM — CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H
- CVSS 2.0 ([email protected])
- 3.5 LOW — AV:N/AC:M/Au:S/C:N/I:N/A:P
- Weaknesses
- CWE-20
Description
Due to a lack of file length check, the HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier crashes when trying to load an empty *.JPR application file. An attacker with access to the file system might be able to cause application malfunction such as denial of service.
Affected configurations
• abb pb610 panel builder 600 (<= 2.8.0.424)
Related
Weakness · CWE (1)
- CWE-20 Improper Input Validation weakness