CVEvulnerability

CVE-2019-18996

7.8 HIGH Published 2019-12-18 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2019-12-18
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.1 ([email protected])
7.1 HIGH — CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:N/I:H/A:L
CVSS 3.1 ([email protected])
7.8 HIGH — CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CVSS 2.0 ([email protected])
4.4 MEDIUM — AV:L/AC:M/Au:N/C:P/I:P/A:P
Weaknesses
CWE-424, CWE-426

Description

Path settings in HMIStudio component of ABB PB610 Panel Builder 600 versions 2.8.0.424 and earlier accept DLLs outside of the program directory, potentially allowing an attacker with access to the local file system the execution of code in the application’s context.

Affected configurations

• abb pb610 panel builder 600 (<= 2.8.0.424)

Related

Weakness · CWE (2)

  • CWE-424 Improper Protection of Alternate Path weakness
  • CWE-426 Untrusted Search Path weakness