CVEvulnerability

CVE-2019-18997

7.5 HIGH Published 2019-12-18 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2019-12-18
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.1 ([email protected])
4.3 MEDIUM — CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L
CVSS 3.1 ([email protected])
7.5 HIGH — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
CVSS 2.0 ([email protected])
5.0 MEDIUM — AV:N/AC:L/Au:N/C:P/I:N/A:N
Weaknesses
CWE-424

Description

The HMISimulator component of ABB PB610 Panel Builder 600 uses the readFile/writeFile interface to manipulate the work file. Path configuration in PB610 HMISimulator versions 2.8.0.424 and earlier potentially allows access to files outside of the working directory, thus potentially supporting unauthorized file access.

Affected configurations

• abb pb610 panel builder 600 (<= 2.8.0.424)

Related

Weakness · CWE (1)

  • CWE-424 Improper Protection of Alternate Path weakness

References