CVEvulnerability
CVE-2019-25276
8.5 HIGH
Official page ↗
- Status
- Deferred
- Published
- 2026-02-05
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 4.0 ([email protected])
- 8.5 HIGH — CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- CVSS 3.1 ([email protected])
- 7.8 HIGH — CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Weaknesses
- CWE-428
Description
Studio 5000 Logix Designer 30.01.00 contains an unquoted service path vulnerability in the FactoryTalk Activation Service that allows local users to potentially execute code with elevated privileges. Attackers can exploit the unquoted path in C:\Program Files (x86)\Rockwell Software\FactoryTalk Activation\ to inject malicious code that would execute with LocalSystem permissions.
Related
Weakness · CWE (1)
- CWE-428 Unquoted Search Path or Element weakness
References
- https://www.exploit-db.com/exploits/47676 www.exploit-db.com
- https://www.rockwellautomation.com/en_NA/overview.page www.rockwellautomation.com
- https://www.vulncheck.com/advisories/studio-logix-designer-factorytalk-activation-service-unquoted-service-path www.vulncheck.com