CVEvulnerability

CVE-2020-10270

9.8 CRITICAL Published 2020-06-24 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2020-06-24
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.1 ([email protected])
9.8 CRITICAL — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 3.0 ([email protected])
9.8 CRITICAL — CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0 ([email protected])
5.0 MEDIUM — AV:N/AC:L/Au:N/C:P/I:N/A:N
Weaknesses
CWE-798

Description

Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000.

Affected configurations

• aliasrobotics mir100 firmware (<= 2.8.1.1) • aliasrobotics mir200 firmware (<= 2.8.1.1) • aliasrobotics mir250 firmware (<= 2.8.1.1) • aliasrobotics mir500 firmware (<= 2.8.1.1) • aliasrobotics mir1000 firmware (<= 2.8.1.1) • mobile-industrial-robotics er200 firmware (<= 2.8.1.1) • enabled-robotics er-lite firmware (<= 2.8.1.1) • enabled-robotics er-flex firmware (<= 2.8.1.1) • enabled-robotics er-one firmware (<= 2.8.1.1) • uvd-robots uvd robots firmware (<= 2.8.1.1)

Related

Weakness · CWE (1)

  • CWE-798 Use of Hard-coded Credentials weakness

References