CVE-2020-12001

9.8 CRITICAL Published 2020-06-15 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2020-06-15
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.1 ([email protected])
9.8 CRITICAL — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 2.0 ([email protected])
7.5 HIGH — AV:N/AC:L/Au:N/C:P/I:P/A:P
Weaknesses
CWE-20

Description

FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. The parsing mechanism that processes certain file types does not provide input sanitation. This may allow an attacker to use specially crafted files to traverse the file system and modify or expose sensitive data or execute arbitrary code.

Affected configurations

• rockwellautomation factorytalk linx 6.00 • rockwellautomation factorytalk linx 6.10 • rockwellautomation factorytalk linx 6.11 • rockwellautomation rslinx classic (<= 4.11.00)