CVEvulnerability

CVE-2020-12034

8.2 HIGH Published 2020-05-20 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2020-05-20
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.1 ([email protected])
8.2 HIGH — CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:L/A:H
CVSS 2.0 ([email protected])
4.8 MEDIUM — AV:A/AC:L/Au:N/C:N/I:P/A:P
Weaknesses
CWE-89

Description

Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions.

Affected configurations

• rockwellautomation eds subsystem (<= 28.0.1) • rockwellautomation rslinx (<= 4.11.00) • rockwellautomation rslinx enterprise 6.00.00 • rockwellautomation rslinx enterprise 6.10.00 • rockwellautomation rslinx enterprise 6.11.00 • rockwellautomation rsnetworx (<= 28.00.00) • rockwellautomation studio 5000 logix designer (<= 32.0)

Related

Weakness · CWE (1)

  • CWE-89 Improper Neutralization of Special Elements used in an SQL Command weakness

References