CVEvulnerability
CVE-2020-12834
9.8 CRITICAL
Official page ↗
- Status
- Modified
- Published
- 2020-05-15
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 3.1 ([email protected])
- 9.8 CRITICAL — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- CVSS 2.0 ([email protected])
- 7.5 HIGH — AV:N/AC:L/Au:N/C:P/I:P/A:P
- Weaknesses
- CWE-276
Description
eQ-3 Homematic Central Control Unit (CCU)2 through 2.51.6 and CCU3 through 3.51.6 allow Remote Code Execution in the JSON API Method ReGa.runScript, by unauthenticated attackers with access to the web interface, due to the default auto-login feature being enabled during first-time setup (or factory reset).
Affected configurations
• eq-3 homematic ccu2 firmware (<= 2.51.6)
• eq-3 ccu3 firmware (<= 3.51.6)
Related
Weakness · CWE (1)
- CWE-276 Incorrect Default Permissions weakness
References
- https://psytester.github.io/CVE-2020-12834/ Exploit, Third Party Advisory
- https://psytester.github.io/CVE-2020-12834/ Exploit, Third Party Advisory