CVEvulnerability
CVE-2020-1634
7.5 HIGH
Official page ↗
- Status
- Modified
- Published
- 2020-04-08
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 3.1 ([email protected])
- 7.5 HIGH — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- CVSS 3.1 ([email protected])
- 7.5 HIGH — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- CVSS 2.0 ([email protected])
- 4.3 MEDIUM — AV:N/AC:M/Au:N/C:N/I:N/A:P
- Weaknesses
- CWE-190
Description
On High-End SRX Series devices, in specific configurations and when specific networking events or operator actions occur, an SPC receiving genuine multicast traffic may core. Subsequently, all FPCs in a chassis may reset causing a Denial of Service. This issue affects both IPv4 and IPv6. This issue affects: Juniper Networks Junos OS 12.3X48 version 12.3X48-D80 and later versions prior to 12.3X48-D95 on High-End SRX Series. This issue does not affect Branch SRX Series devices.
Affected configurations
• juniper junos 12.3x48
Related
Weakness · CWE (1)
- CWE-190 Integer Overflow or Wraparound weakness
References
- https://kb.juniper.net/JSA11014 Vendor Advisory
- https://kb.juniper.net/JSA11014 Vendor Advisory