CVEvulnerability
CVE-2021-21599
6.7 MEDIUM
Official page ↗
- Status
- Modified
- Published
- 2021-08-16
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 3.1 ([email protected])
- 6.0 MEDIUM — CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H
- CVSS 3.1 ([email protected])
- 6.7 MEDIUM — CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- CVSS 2.0 ([email protected])
- 4.6 MEDIUM — AV:L/AC:L/Au:N/C:P/I:P/A:P
- Weaknesses
- CWE-78
Description
Dell EMC PowerScale OneFS versions 8.2.x - 9.2.1.x contain an OS command injection vulnerability. This may allow a user with ISI_PRIV_LOGIN_SSH or ISI_PRIV_LOGIN_CONSOLE to escalate privileges and escape the compliance guarantees. This only impacts Smartlock WORM compliance mode clusters as a critical vulnerability and Dell recommends to update/upgrade at the earliest opportunity.
Affected configurations
• dell emc powerscale onefs (>= 9.0.0.0 <= 9.2.1)
• dell emc powerscale onefs 8.2.2
Related
Weakness · CWE (1)
- CWE-78 Improper Neutralization of Special Elements used in an OS Command weakness
References
- https://www.dell.com/support/kbdoc/000190408 Patch, Vendor Advisory
- https://www.dell.com/support/kbdoc/000190408 Patch, Vendor Advisory