CVEvulnerability

CVE-2021-27196

7.5 HIGH Published 2021-06-14 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2021-06-14
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.1 ([email protected])
7.5 HIGH — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CVSS 3.1 ([email protected])
7.5 HIGH — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
CVSS 2.0 ([email protected])
5.0 MEDIUM — AV:N/AC:L/Au:N/C:N/I:N/A:P
Weaknesses
CWE-20

Description

Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU500 Series, FOX615 (TEGO1), MSM, GMS600, PWC600 allows an attacker with access to the IEC 61850 network with knowledge of how to reproduce the attack, as well as the IP addresses of the different IEC 61850 access points (of IEDs/products), to force the device to reboot, which renders the device inoperable for approximately 60 seconds. This vulnerability affects only products with IEC 61850 interfaces. This issue affects: Hitachi ABB Power Grids Relion 670 Series 1.1; 1.2.3 versions prior to 1.2.3.20; 2.0 versions prior to 2.0.0.13; 2.1; 2.2.2 versions prior to 2.2.2.3; 2.2.3 versions prior to 2.2.3.2. Hitachi ABB Power Grids Relion 670/650 Series 2.2.0 versions prior to 2.2.0.13. Hitachi ABB Power Grids Relion 670/650/SAM600-IO 2.2.1 versions prior to 2.2.1.6. Hitachi ABB Power Grids Relion 650 1.1; 1.2; 1.3 versions prior to 1.3.0.7. Hitachi ABB Power Grids REB500 7.3; 7.4; 7.5; 7.6; 8.2; 8.3. Hitachi ABB Power Grids RTU500 Series 7.x version 7.x and prior versions; 8.x version 8.x and prior versions; 9.x version 9.x and prior versions; 10.x version 10.x and prior versions; 11.x version 11.x and prior versions; 12.x version 12.x and prior versions. Hitachi ABB Power Grids FOX615 (TEGO1) R1D02 version R1D02 and prior versions. Hitachi ABB Power Grids MSM 2.1.0 versions prior to 2.1.0. Hitachi ABB Power Grids GMS600 1.3.0 version 1.3.0 and prior versions. Hitachi ABB Power Grids PWC600 1.0 versions prior to 1.0.1.4; 1.1 versions prior to 1.1.0.1.

Affected configurations

• hitachienergy relion 670 firmware (>= 1.2.3 < 1.2.3.20) • hitachienergy relion 670 firmware (>= 2.0 < 2.0.0.13) • hitachienergy relion 670 firmware (>= 2.2.0 < 2.2.0.13) • hitachienergy relion 670 firmware (>= 2.2.1 < 2.2.1.6) • hitachienergy relion 670 firmware (>= 2.2.2 < 2.2.2.3) • hitachienergy relion 670 firmware (>= 2.2.3 < 2.2.3.2) • hitachienergy relion 670 firmware 1.1 • hitachienergy relion 670 firmware 2.1 • hitachienergy relion 650 firmware (>= 1.3 < 1.3.0.7) • hitachienergy relion 650 firmware (>= 2.2.0 < 2.2.0.13) • hitachienergy relion 650 firmware (>= 2.2.1 < 2.2.1.6) • hitachienergy relion 650 firmware 1.1 • hitachienergy relion 650 firmware 1.2 • hitachienergy relion 650 firmware 2.1 • hitachienergy relion sam600-io firmware (>= 2.2.1 < 2.2.1.6) • hitachienergy rtu500 firmware 7.0 • hitachienergy rtu500 firmware 8.0 • hitachienergy rtu500 firmware 9.0 • hitachienergy rtu500 firmware 10.0 • hitachienergy rtu500 firmware 11.0 • hitachienergy rtu500 firmware 12.0 • hitachienergy reb500 firmware (>= 7.3 < 7.60.19) • hitachienergy reb500 firmware (>= 8.2 < 8.2.0.5) • hitachienergy reb500 firmware (>= 8.3 <= 8.3.1.0) • hitachienergy fox615 tego1 firmware (< r2a16) • hitachienergy modular switchgear monitoring firmware (< 2.1.0) • hitachienergy gms600 firmware (<= 1.3.0) • hitachienergy pwc600 firmware (>= 1.0 < 1.0.1.4) • hitachienergy pwc600 firmware (>= 1.1 < 1.1.0.1)

Related

Weakness · CWE (1)

  • CWE-20 Improper Input Validation weakness

References