CVEvulnerability
CVE-2021-27465
6.1 MEDIUM
Official page ↗
- Status
- Modified
- Published
- 2021-05-20
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 3.1 ([email protected])
- 6.1 MEDIUM — CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
- CVSS 2.0 ([email protected])
- 4.3 MEDIUM — AV:N/AC:M/Au:N/C:N/I:P/A:N
- Weaknesses
- CWE-79
Description
A vulnerability has been found in multiple revisions of Emerson Rosemount X-STREAM Gas Analyzer. The affected applications do not validate webpage input, which could allow an attacker to inject arbitrary HTML code into a webpage. This would allow an attacker to modify the page and display incorrect or undesirable data.
Affected configurations
• emerson x-stream enhanced xegp firmware
• emerson x-stream enhanced xegk firmware
• emerson x-stream enhanced xefd firmware
• emerson x-stream enhanced xexf firmware
Related
Weakness · CWE (1)
- CWE-79 Improper Neutralization of Input During Web Page Generation weakness
References
- https://us-cert.cisa.gov/ics/advisories/icsa-21-138-01 Third Party Advisory, US Government Resource
- https://us-cert.cisa.gov/ics/advisories/icsa-21-138-01 Third Party Advisory, US Government Resource