CVEvulnerability

CVE-2022-1118

7.8 HIGH Published 2022-05-17 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2022-05-17
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.1 ([email protected])
8.6 HIGH — CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H
CVSS 3.1 ([email protected])
7.8 HIGH — CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
CVSS 2.0 ([email protected])
6.8 MEDIUM — AV:N/AC:M/Au:N/C:P/I:P/A:P
Weaknesses
CWE-502

Description

Connected Components Workbench (v13.00.00 and prior), ISaGRAF Workbench (v6.0 though v6.6.9), and Safety Instrumented System Workstation (v1.2 and prior (for Trusted Controllers)) do not limit the objects that can be deserialized. This allows attackers to craft a malicious serialized object that, if opened by a local user in Connected Components Workbench, may result in arbitrary code execution. This vulnerability requires user interaction to be successfully exploited

Affected configurations

• rockwellautomation connected component workbench (<= 13.00.00) • rockwellautomation isagraf workbench (>= 6.0 <= 6.6.9) • rockwellautomation safety instrumented systems workstation (<= 1.2)

Related

Weakness · CWE (1)

  • CWE-502 Deserialization of Untrusted Data weakness

References