CVEvulnerability

CVE-2022-1368

9.8 CRITICAL Published 2022-09-06 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2022-09-06
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.1 ([email protected])
9.8 CRITICAL — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
CVSS 3.1 ([email protected])
9.8 CRITICAL — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weaknesses
CWE-306

Description

The Cognex 3D-A1000 Dimensioning System in firmware version 1.0.3 (3354) and prior is vulnerable to CWE-306: Missing Authentication for Critical Function, which allows unauthorized users to change the operator account password via webserver commands by monitoring web socket communications from an unauthenticated session. This could allow an attacker to escalate privileges to match those of the compromised account.

Affected configurations

• cognex 3d-a1000 dimensioning system firmware (<= 1.0.3\(3354\))

Related

Weakness · CWE (1)

  • CWE-306 Missing Authentication for Critical Functionality weakness

References