CVEvulnerability
CVE-2022-25164
7.5 HIGH
Official page ↗
- Status
- Modified
- Published
- 2022-11-25
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 3.1 ([email protected])
- 8.6 HIGH — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N
- CVSS 3.1 ([email protected])
- 7.5 HIGH — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- Weaknesses
- CWE-312
Description
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.
Affected configurations
• mitsubishielectric gx works3 (>= 1.000a <= 1.011m)
• mitsubishielectric gx works3 (>= 1.015r <= 1.086q)
• mitsubishielectric gx works3 (>= 1.087r)
• mitsubishielectric mx opc ua module configurator-r
Related
Weakness · CWE (1)
- CWE-312 Cleartext Storage of Sensitive Information weakness
References
- https://jvn.jp/vu/JVNVU97244961/index.html Third Party Advisory, VDB Entry
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05 www.cisa.gov
- https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf Mitigation, Vendor Advisory
- https://jvn.jp/vu/JVNVU97244961/index.html Third Party Advisory, VDB Entry
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-333-05 www.cisa.gov
- https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-015_en.pdf Mitigation, Vendor Advisory