CVEvulnerability

CVE-2022-31807

5.9 MEDIUM Published 2025-05-23 Modified 2026-06-17 Official page ↗
Status
Modified
Published
2025-05-23
Last modified
2026-06-17
Assigner
[email protected]
CVSS 4.0 ([email protected])
5.9 MEDIUM — CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1 ([email protected])
6.2 MEDIUM — CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N
CVSS 3.1 ([email protected])
5.5 MEDIUM — CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N
Weaknesses
CWE-347

Description

A vulnerability has been identified in Building X - Security Manager Edge Controller (ACC-AP) (All versions). Affected devices do not properly check the integrity of firmware updates. This could allow a local attacker to upload a maliciously modified firmware onto the device. In a second scenario, a remote attacker who is able to intercept the transfer of a valid firmware from the server to the device could modify the firmware "on the fly".

Affected configurations

• siemens sipass integrated ac5102 \(acc-g2\) firmware • siemens sipass integrated acc-ap firmware

Related

Weakness · CWE (1)

  • CWE-347 Improper Verification of Cryptographic Signature weakness

References