CVEvulnerability
CVE-2022-3214
9.8 CRITICAL
Official page ↗
- Status
- Modified
- Published
- 2022-09-16
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 3.1 ([email protected])
- 9.8 CRITICAL — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- CVSS 3.1 ([email protected])
- 9.8 CRITICAL — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- Weaknesses
- CWE-798
Description
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to
1.9.03.009
have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing remote code execution.
Affected configurations
• deltaww diaenergie (< 1.9.03.009)
Related
Weakness · CWE (1)
- CWE-798 Use of Hard-coded Credentials weakness
References
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-256-03 Third Party Advisory, US Government Resource