CVEvulnerability
CVE-2022-33138
7.5 HIGH
Official page ↗
- Status
- Modified
- Published
- 2022-07-12
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 3.1 ([email protected])
- 7.5 HIGH — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- CVSS 2.0 ([email protected])
- 5.0 MEDIUM — AV:N/AC:L/Au:N/C:P/I:N/A:N
- Weaknesses
- CWE-306
Description
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3), SIMATIC MV540 S (All versions < V3.3), SIMATIC MV550 H (All versions < V3.3), SIMATIC MV550 S (All versions < V3.3), SIMATIC MV560 U (All versions < V3.3), SIMATIC MV560 X (All versions < V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device.
Affected configurations
• siemens simatic mv540 h firmware (< 3.3)
• siemens simatic mv540 s firmware (< 3.3)
• siemens simatic mv550 h firmware (< 3.3)
• siemens simatic mv550 s firmware (< 3.3)
• siemens simatic mv560 u firmware (< 3.3)
• siemens simatic mv560 x firmware (< 3.3)
Related
Weakness · CWE (1)
- CWE-306 Missing Authentication for Critical Functionality weakness
References
- https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf Patch, Vendor Advisory
- https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf Patch, Vendor Advisory