CVEvulnerability
CVE-2022-33174
7.5 HIGH
Official page ↗
- Status
- Modified
- Published
- 2022-06-13
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 3.1 ([email protected])
- 9.8 CRITICAL — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
- CVSS 3.1 ([email protected])
- 7.5 HIGH — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
- CVSS 2.0 ([email protected])
- 5.0 MEDIUM — AV:N/AC:L/Au:N/C:P/I:N/A:N
- Weaknesses
- CWE-863
Description
Power Distribution Units running on Powertek firmware (multiple brands) before 3.30.30 allows remote authorization bypass in the web interface. To exploit the vulnerability, an attacker must send an HTTP packet to the data retrieval interface (/cgi/get_param.cgi) with the tmpToken cookie set to an empty string followed by a semicolon. This bypasses an active session authorization check. This can be then used to fetch the values of protected sys.passwd and sys.su.name fields that contain the username and password in cleartext.
Affected configurations
• powertekpdus basic pdu firmware (< 3.30.30)
• powertekpdus pm pdu firmware (< 3.30.30)
• powertekpdus piml pdu firmware (< 3.30.30)
• powertekpdus smart pim firmware (< 3.30.30)
• powertekpdus smart pos firmware (< 3.30.30)
• powertekpdus smart pom firmware (< 3.30.30)
• powertekpdus smart poms firmware (< 3.30.30)
Related
Weakness · CWE (1)
- CWE-863 Incorrect Authorization weakness
References
- https://gynvael.coldwind.pl/?lang=en&id=748 Exploit, Third Party Advisory
- https://gynvael.coldwind.pl/?lang=en&id=748 Exploit, Third Party Advisory