CVEvulnerability
CVE-2022-3382
7.5 HIGH
Official page ↗
- Status
- Modified
- Published
- 2022-10-17
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 3.1 ([email protected])
- 7.5 HIGH — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- CVSS 3.1 ([email protected])
- 7.5 HIGH — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
- Weaknesses
- CWE-284
Description
HIWIN Robot System Software version 3.3.21.9869 does not properly address the terminated command source. As a result, an attacker could craft code to disconnect HRSS and the controller and cause a denial-of-service condition.
Affected configurations
• hiwin robot system software 3.3.21.9869
Related
Weakness · CWE (1)
- CWE-284 Improper Access Control weakness
References
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-279-02 Third Party Advisory, US Government Resource
- https://www.cisa.gov/uscert/ics/advisories/icsa-22-279-02 Third Party Advisory, US Government Resource