CVEvulnerability
CVE-2023-0321
9.1 CRITICAL
Official page ↗
- Status
- Modified
- Published
- 2023-01-26
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 3.1 ([email protected])
- 9.1 CRITICAL — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
- CVSS 3.1 ([email protected])
- 9.1 CRITICAL — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
- Weaknesses
- CWE-200
Description
Campbell Scientific dataloggers CR6, CR300, CR800, CR1000 and CR3000 may allow an attacker to download configuration files, which may contain sensitive information about the internal network. From factory defaults, the mentioned datalogges have HTTP and PakBus enabled. The devices, with the default configuration, allow this situation via the PakBus port. The exploitation of this vulnerability may allow an attacker to download, modify, and upload new configuration files.
Affected configurations
• campbellsci cr6 firmware
• campbellsci cr300 firmware
• campbellsci cr800 firmware
• campbellsci cr1000 firmware
• campbellsci cr3000 firmware
Related
Weakness · CWE (1)
- CWE-200 Exposure of Sensitive Information to an Unauthorized Actor weakness
References
- https://www.hackplayers.com/2023/01/cve-2023-0321-info-sensible-campbell.html Exploit, Third Party Advisory
- https://www.incibe-cert.es/en/early-warning/ics-advisories/disclosure-sensitive-information-campbell-scientific-products Mitigation, Third Party Advisory
- https://www.hackplayers.com/2023/01/cve-2023-0321-info-sensible-campbell.html Exploit, Third Party Advisory
- https://www.incibe-cert.es/en/early-warning/ics-advisories/disclosure-sensitive-information-campbell-scientific-products Mitigation, Third Party Advisory