CVEvulnerability

CVE-2024-10313

8.6 HIGH Published 2024-10-24 Modified 2026-06-17 Official page ↗
Status
Deferred
Published
2024-10-24
Last modified
2026-06-17
Assigner
[email protected]
CVSS 4.0 ([email protected])
8.6 HIGH — CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1 ([email protected])
8.0 HIGH — CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
Weaknesses
CWE-22

Description

iniNet Solutions SpiderControl SCADA PC HMI Editor has a path traversal vulnerability. When the software loads a malicious ‘ems' project template file constructed by an attacker, it can write files to arbitrary directories. This can lead to overwriting system files, causing system paralysis, or writing to startup items, resulting in remote control.

Related

Weakness · CWE (1)

  • CWE-22 Improper Limitation of a Pathname to a Restricted Directory weakness

References