CVEvulnerability

CVE-2024-37143

9.8 CRITICAL Published 2024-12-10 Modified 2026-06-17 Official page ↗
Status
Analyzed
Published
2024-12-10
Last modified
2026-06-17
Assigner
[email protected]
CVSS 3.1 ([email protected])
10.0 CRITICAL — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
CVSS 3.1 ([email protected])
9.8 CRITICAL — CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Weaknesses
CWE-59

Description

Dell PowerFlex appliance versions prior to IC 46.381.00 and IC 46.376.00, Dell PowerFlex rack versions prior to RCM 3.8.1.0 (for RCM 3.8.x train) and prior to RCM 3.7.6.0 (for RCM 3.7.x train), Dell PowerFlex custom node using PowerFlex Manager versions prior to 4.6.1.0, Dell InsightIQ versions prior to 5.1.1, and Dell Data Lakehouse versions prior to 1.2.0.0 contain an Improper Link Resolution Before File Access vulnerability. An unauthenticated attacker with remote access could potentially exploit this vulnerability to execute arbitrary code on the system.

Affected configurations

• dell data lakehouse (< 1.2.0.0) • dell insightiq (< 5.1.1) • dell powerflex appliance intelligent catalog (< 46.376.00) • dell powerflex manager (< 4.6.1.0) • dell powerflex rack release certification matrix (>= 3.7.0.0 < 3.7.6.0) • dell powerflex rack release certification matrix (>= 3.8.0.0 < 3.8.1.0)

Related

Weakness · CWE (1)

  • CWE-59 Improper Link Resolution Before File Access weakness

References