CVEvulnerability
CVE-2024-39568
8.5 HIGH
Official page ↗
- Status
- Modified
- Published
- 2024-07-09
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 4.0 ([email protected])
- 8.5 HIGH — CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- CVSS 3.1 ([email protected])
- 7.8 HIGH — CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- CVSS 3.1 ([email protected])
- 7.8 HIGH — CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
- Weaknesses
- CWE-77
Description
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 HF1). The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading proxy configurations. This could allow an authenticated local attacker to execute arbitrary code with system privileges.
Affected configurations
• siemens sinema remote connect client (< 3.2)
• siemens sinema remote connect client 3.2
Related
Weakness · CWE (1)
- CWE-77 Improper Neutralization of Special Elements used in a Command weakness
References
- https://cert-portal.siemens.com/productcert/html/ssa-868282.html Patch, Vendor Advisory
- https://cert-portal.siemens.com/productcert/html/ssa-868282.html Patch, Vendor Advisory