CVEvulnerability
CVE-2024-39569
7.5 HIGH
Official page ↗
- Status
- Modified
- Published
- 2024-07-09
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 4.0 ([email protected])
- 7.5 HIGH — CVSS:4.0/AV:N/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- CVSS 3.1 ([email protected])
- 6.6 MEDIUM — CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H
- CVSS 3.1 ([email protected])
- 7.2 HIGH — CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
- Weaknesses
- CWE-77
Description
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.2 HF1). The system service of affected applications is vulnerable to command injection due to missing server side input sanitation when loading VPN configurations. This could allow an administrative remote attacker running a corresponding SINEMA Remote Connect Server to execute arbitrary code with system privileges on the client system.
Affected configurations
• siemens sinema remote connect client (< 3.2)
• siemens sinema remote connect client 3.2
Related
Weakness · CWE (1)
- CWE-77 Improper Neutralization of Special Elements used in a Command weakness
References
- https://cert-portal.siemens.com/productcert/html/ssa-868282.html Patch, Vendor Advisory
- https://cert-portal.siemens.com/productcert/html/ssa-868282.html Patch, Vendor Advisory