CVEvulnerability
CVE-2024-46890
9.4 CRITICAL
Official page ↗
- Status
- Analyzed
- Published
- 2024-11-12
- Last modified
- 2026-06-17
- Assigner
- [email protected]
- CVSS 4.0 ([email protected])
- 9.4 CRITICAL — CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
- CVSS 3.1 ([email protected])
- 9.1 CRITICAL — CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H
- Weaknesses
- CWE-78
Description
A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly validate input sent to specific endpoints of its web API. This could allow an authenticated remote attacker with high privileges on the application to execute arbitrary code on the underlying OS.
Affected configurations
• siemens sinec ins (< 1.0)
• siemens sinec ins 1.0
Related
Weakness · CWE (1)
- CWE-78 Improper Neutralization of Special Elements used in an OS Command weakness
References
- https://cert-portal.siemens.com/productcert/html/ssa-915275.html Vendor Advisory