CVEvulnerability

CVE-2024-53242

7.3 HIGH Published 2024-12-10 Modified 2026-06-17 Official page ↗
Status
Analyzed
Published
2024-12-10
Last modified
2026-06-17
Assigner
[email protected]
CVSS 4.0 ([email protected])
7.3 HIGH — CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1 ([email protected])
7.8 HIGH — CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Weaknesses
CWE-125

Description

A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25206)

Affected configurations

• siemens teamcenter visualization (>= 14.2 < 14.2.0.14) • siemens teamcenter visualization (>= 14.3 < 14.3.0.12) • siemens teamcenter visualization (>= 2312.0 < 2312.0008) • siemens tecnomatix plant simulation (>= 2302.0 < 2302.0016) • siemens tecnomatix plant simulation (>= 2404.0 < 2404.0005)

Related

Weakness · CWE (1)

  • CWE-125 Out-of-bounds Read weakness

References