CVEvulnerability

CVE-2024-7847

8.8 HIGH Published 2024-10-14 Modified 2026-06-17 Official page ↗
Status
Analyzed
Published
2024-10-14
Last modified
2026-06-17
Assigner
[email protected]
CVSS 4.0 ([email protected])
8.8 HIGH — CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
CVSS 3.1 ([email protected])
7.7 HIGH — CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H
CVSS 3.1 ([email protected])
7.8 HIGH — CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
Weaknesses
CWE-345

Description

VULNERABILITY DETAILS Rockwell Automation used the latest versions of the CVSS scoring system to assess the following vulnerabilities. The following vulnerabilities were reported to us by Sharon Brizinov of Claroty Research - Team82. A feature in the affected products enables users to prepare a project file with an embedded VBA script and can be configured to run once the project file has been opened without user intervention. This feature can be abused to trick a legitimate user into executing malicious code upon opening an infected RSP/RSS project file. If exploited, a threat actor may be able to perform a remote code execution. Connected devices may also be impacted by exploitation of this vulnerability.

Affected configurations

• rockwellautomation rslogix 5 • rockwellautomation rslogix 500 • rockwellautomation rslogix micro developer • rockwellautomation rslogix micro starter lite

Related

Weakness · CWE (1)

  • CWE-345 Insufficient Verification of Data Authenticity weakness

References