CVEvulnerability

CVE-2025-11500

8.7 HIGH Published 2026-03-16 Modified 2026-06-17 Official page ↗
Status
Deferred
Published
2026-03-16
Last modified
2026-06-17
Assigner
[email protected]
CVSS 4.0 ([email protected])
8.7 HIGH — CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Weaknesses
CWE-201, CWE-261

Description

Tinycontrol devices such as tcPDU and LAN Controllers LK3.5, LK3.9 and LK4 have two separate authentication mechanisms - one solely for interface management and one for protecting all other server resources. When the latter is turned off (which is a default setting), an unauthenticated attacker on the local network can obtain usernames and encoded passwords for interface management portal by inspecting the HTTP response of the server when visiting the login page, which contains a JSON file with these details. Both normal and admin users credentials are exposed.  This issue has been fixed in firmware versions: 1.36 (for tcPDU), 1.67 (for LK3.5 - hardware versions: 3.5, 3.6, 3.7 and 3.8), 1.75 (for LK3.9 - hardware version 3.9) and 1.38 (for LK4 - hardware version 4.0).

Related

Weakness · CWE (2)

  • CWE-201 Insertion of Sensitive Information Into Sent Data weakness
  • CWE-261 Weak Encoding for Password weakness

References